Journal Publications


Park, H., Zhang, S., Steinman, A., Chen, Z., and Lee, H., Graphene prevents neurostimulation-induced platinum dissolution in fractal microelectrodes. 2D Materials, 6, 035037, 2019. 

Dhowan, D., Lim, J., MacLean, M. D., Berman, A. G., Kim, M. K,, Yang, Q., Linnes, J., Lee, C. H., Goergen, C. J., Lee, H. Simple minimally-invasive automatic antidote delivery device (A2D2) towards closed-loop reversal of opioid overdose. Journal of Controlled Release, 306, pp. 130-137, 2019.

Nguyen, T. N. H., Nolan, J. K., Park, H., Lam, S., Fattah, M., Joe, H-E, Lee, H., Kim, S. J., Jun, M. B. G., Shi, R., and Lee, H. Facile fabrication of glutamate biosensor using direct writing of platinum nanoparticle-based nanocomposite ink. Biosensors and Bioelectronics, 135, 15, pp. 257-266, 2019.

Yang, Q., Lee, A., Bentley, R. T., and Lee, H. Piezoeresistor-embedded multifunctional magnetic microactuators for implantable self-clearing catheter. IEEE Sensors Journal, 19, 4, pp. 1373-1378, 2019.

Park, H., Raffiee, A. H., John, S. W. M., Ardekani, A. M., and Lee, H. Towards smart self-clearing glaucoma drainage device. Microsytems and Nanoengineering, 4, 35, 2018.

Yang, Q., Park, H., Nguyen, T. N. H., Rhoads, J. F., Lee, A., Bentley, R. T., Judy, J. W., and Lee, H. Anti-biofouling implantable catheter using thin-film magnetic microactuators. Sensors and Actuators B: Chemical, 273, pp. 1694-1704, 2018.

Park, H, Takmakov, P., and Lee, H. Electrochemical evaluations of fractal microelectrodes for energy efficient neurostimulation. Scientific Reports, 8, 4375, 2018.

Kumsa, D., Steinke, G. K., Molnar, G. F., Hudak, E. M., Montague, F. W., Kelley, S. C., Unterreker, D. F., Shi, A., Hahn, B. P., Condit, C., Lee, H., Bardot, D., Centeno, J. A., Krauthamer, V., and Takmakov, P. A. Public regulatory databases as a source of insight for neuromodulation devices stimulation. Neuromodulation, 21, pp. 117-125, 2018.

Kumsa, D., Mortimer, J. T., Hudak, E. M., Montague, F. W., Kelley, S. C., Untereker, D. F., Hahn, B., Condit, C., Cholette, M., Lee, H., Bardot, D., and Takmakov, P. Electrical neurostimulation with imbalanced waveform mitigates dissolution of platinum electrodes. Journal of Neural Engineering, 13(5), pp. 054001 (5pp), 2016.

Lee, H., Kolahi, K., Bergsneider, M., and Judy, J. Mechanical evaluation of unobstructing magnetic microactuators for implantable ventricular catheters. Journal of Microelectromechanical Systems, 23(4), pp.795-802, 2014.

Lee, H., Xu, Q., Shellock, F., Bergsneider, M., and Judy, J. Evaluation of magnetic reso- nance imaging issues for implantable microfabricated magnetic actuators. Biomedical Microdevices, 16(1), pp. 153-161, 2014.

Iyer, S. S., Vedad-Ghavami, R., Lee, H., Liger, M., Kavehpour, H. P., and Candler, R. N. Nonlinear damping for vibration isolation of microsystems using shear thickening fluid. Applied Physics Letters, 102, 251902, 2013.

Lee, S. A., Lee, H., Pinney, J, Khialeeva, E., Bergsneider, M., and Judy, J. Development of microfabricated magnetic actuators for cellular occlusion removal. Journal of Micromechanics and Microengineering, 21, 054006, 2011.

Isobe, J., Velez, F., Lee, H., Patnode, S., Judy, J., and Rosenbaum, A. In vivo functional electrical stimulation of feline lateral rectus: Relationship between stimulation parameters and eye rotation in denervated muscle. Artificial Organs, 31(8), August 2008.

Anderson, K., Bones, B., Robinson, B., Hass, C., Lee, H., Ford, K., Roberts, T., and Jacobs, B. The morphology of supragranular pyramidal neurons in the human insular cortex: A quantitative Golgi study. Cerebral Cortex, 19(9), January 2009.

Conference Presentations


Yang, Q., Lee, A., Bentley, R. T., and Lee., H. Improved shunt survival with MEMS-enabled ventricular catheter in treatment of intraventricular hemorrhage. IEEE EMBC Micro and Nanotechnology in Medicine Conference, Dec, 2018.

Nguyen, T., Lam, S., Park, H., Shi, R., and Lee. H. Development of flexible glutamate biosensor using activated carbon – Pt microparticle composite ink. IEEE Sensors 2018, Oct, 2018.

Ayad, M., Nawrocki, R., Voyles, R., Lee, J., Lee, H, and Leon-Salas, D. Towards rapid-prototyping of robotic materials that can sense, think, and act. SMASIS 2018, Sep, 2018.

Moon, H., Voytik-Harbin, S., and Lee, H. Impact of type I collagen on chronic implantable microdevices. IU-Purdue Bioengineering Training in Diabetes Research Conference, Aug, 2018.

Bentley, R. T., Yang, Q., Thomovsky, S. A., Lyle, L. T., and Lee, H. Development of an intraventricular hemorrhage model of obstructive hydrocephalus in pigs. 2018 ACVIM Forum Jul, 2018.

Park, H., Takmakov, P., and Lee, H. Effect of surface area to perimeter ratio on charge storage capacity of microelectrodes for neurostimulation. 232nd ECS Meeting, Oct, 2017.

Yang, Q., and Lee, H. Strain gauge integrated implantable magnetic microactuators. EMBC 2017, Aug, 2017.

Nguyen, T., Lam, S., Shi, R., and Lee, H. Rapid prototyping of microscale and flexible electrochemical biosensors using direct write. EMBC 2017, Aug, 2017.

Yang, Q., and Lee, H. Anti-biofouling implantable magnetic microactuators with integrated piezoresistive sensor. BMES 2017, Oct, 2017.

Park, H., John. S., and Lee, H. Anti-biofouling microtubes for glaucoma drainage devices. BMES 2017, Oct, 2017.

Yang, Q. Rhoads, J., and Lee, H. Mechanical responses of flexible magnetic microactuators for biofouling removal. BMES 2016, Oct, 2016.

Park, H., John. S., and Lee, H. Mechanical response of liquid crystal polymer based magnetic microactuators for glaucoma drainage device. BMES 2016, Oct, 2016.

Nguyen, T., Linnes, J., and Lee, H., Bacteria removal capabilities of polyimide-based magnetic microactuators. BMES 2016, Oct, 2016.

Yang, Q., Nguyen, T., Liu, C., Miller, J., Rhoads, J. F., Linnes, J., and Lee, H. Polyimide-based magnetic microactuators for biofouling removal. EMBC 2016, Aug, 2016.

Park, H., John, S., and Lee, H. Low-cost rapid prototyping of liquid crystal polymer based magnetic microactuators for glaucoma drainage devices. EMBC 2016, Aug, 2016.

Lee, H., and Cernera, S. Towards in situ measurements of platinum dissolution using methallothionein-based biosensor. BMES 2015, Oct, 2015.

Lee, H., Xu, Q., Bergsneider, M., and Judy, J. MRI compatibility of microfabricated magnetic actuators for implantable catheters: Mechanical Evaluations. In: Proceedings of the 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. August 31-September 4, 2010.

Lee, H., Lee, S. A., Bergsneider, M., and Judy, J. Unobstructing magnetic microactuators for implantable catheters. In: Proceedings of the 15th International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers), June 21-25, 2009

Velez, F. G, Isobe, J., Zealear, D., Judy, J. W., Edgerton, V. R., Patnode, S., Lee, H. and Hahn, B. T., Toward an implantable functional electrical stimulation device to correct strabismus, Presented at the 34th Annual Meeting of the American Association for Pediatric Ophthalmology and Strabismus, Washington, DC, April 2-6, 2008.

Lee, H., Matthews, B., Miu, T., and Judy, J. Effects of surface treatments and pre-patch suction time on patch-clamp seal impedance. In: Proceedings of the 2007 BMES Annual Fall Meeting, September 26-29, 2007.

Lee, H. W., Travis, K., Hass, C., and Jacobs, B. Regional dendritic variation in human insular cortex: A quantitative Golgi analysis. In: Proceedings of the 2004 Society for Neuroscience Conference, 2004.