Lab 6b Tips: Permanent-Magnet Synchronous Motor
In-lab
- You can complete the entire lab with this one model.
Check your work.
- P = 8 poles
- λ'm ≈ 0.0037 Nm/A or Vs/rad
- rs ≈ 0.27 Ω
- Lss ≈ 0.28 mH
Post-lab
- Question 1 can be completed in the in-lab or the post-lab. There are three parts:
- Describing and explaining what happens when phases b and c are swapped
- Relating fT (frequency of torque pulsation) to we (frequency of applied voltages) and explaining the relationship
- Showing .